Deep Vein Thrombosis (DVT) Prevention and Treatment Product (QJ-B100)
Deep Vein Thrombosis (DVT) Prevention and Treatment Product(QJ-B100)
Technical Specifications
-
Screen and Operation
-
5-inch capacitive touchscreen
-
Based on the T5L1 chip
-
DGUS II operating system
-
Resolution: 480 × 854
-
16.7 million colors
-
-
Treatment Modes
-
Manual Treatment
-
Standard Treatment
-
-
Treatment Pressure
-
Maximum treatment pressure: 300 mmHg
-
Minimum treatment pressure: 0 mmHg
-
Pressure adjustment accuracy: 1 mmHg
-
Relevant parameter documentation shall be provided as required by the applicable national regulatory authority.
-
-
Treatment Functions
-
Supports both plantar foot pressure cuffs and calf pressure cuffs for treatment.
-
-
Device Indication Functions
-
During operation, the screen displays treatment time and pressure.
-
The deviation between the displayed pressure and the actual measured pressure shall not exceed ±5 mmHg.
-
Overpressure warning
-
Underpressure warning
-
Fault warning
-
Dynamic treatment-site indication: the treatment site currently being treated flashes on the screen.
-
-
Overpressure Protection
-
The device incorporates dual overpressure protection through both software and hardware safeguards.
-
In the event of overpressure, the device provides an overpressure warning and automatically releases the air pressure inside the chambers.
-
Under a single-fault condition, the system is designed to release the maximum pressure in the chambers and connecting tubing.
-
The pressure delivered to the limb shall not exceed 120% of the maximum treatment pressure for more than 1 second.
-
Relevant parameter documentation shall be provided as required by the applicable national regulatory authority.
-
-
Function Control
-
The device is equipped with an output stop switch, allowing the treatment procedure to be interrupted at any time.
-
-
Fault Self-Inspection
-
The device is equipped with a fault self-inspection function.
-
-
Pulse Width and Refill Time
-
Adjustable pulse width: Levels 1–5
-
Adjustable refill time: 20–70 seconds
-
-
Pressure Release Measures
The device provides pressure-release measures under the following conditions:
a. Manual pressure release:
The patient pressure can be manually released under various operating conditions. Disconnecting the ventilation tubing is sufficient to release the pressure.
b. Completion of treatment:
Automatic pressure release occurs when the preset treatment time is reached and the treatment program is completed.
c. Power interruption:
Automatic pressure release occurs in the event of sudden loss of power.
d. Device fault:
Automatic pressure release occurs when a fault is detected and a fault warning is triggered.
e. Temporary treatment interruption:
Automatic pressure release occurs when the treatment program is temporarily interrupted.
In all of the above situations, pressure release shall be completed with a single action. The time required for the patient pressure to decrease from the maximum pressure to 2 kPa shall not exceed 10 seconds.
-
Installation and Mounting
-
Suitable for bedside use.
-
Can also be mounted on a dedicated medical trolley.
-
Safety and Pressure Resistance
-
The chambers and connecting tubing shall withstand a pressure of 450 mmHg for 1 minute without rupture or permanent (plastic) deformation.
-
Connections shall remain secure without loosening or visible deformation.
-
The chambers and connecting tubing shall withstand sudden external forces without localized bulging or rupture.